Valvcon Actuator Models and Options
|
Model |
Description |
Quarter-Turn Actuators Built for Hard Work |
|
Back-up Power Protection for an AC Power Loss Situation |
|
Reliable Back-Up Power for ON/Off Service |
|
Low Cost, Reversing and Uni-directional Electric Actuators |
|
Q6 Series |
Oil Field Service and Remote Applications |
"Series", "Enclosures", "Torque", "Duty Cycle", "Voltage" and "Control Signal" selections are mandatory. "Board Options" limited to one per unit. "Other Options" may have mutliple selections. Consult your Valvcon Representative for assistance in determining compatible options.
Series |
Enclosure |
Torque (Breakaway) |
Board Option |
Other Options |
Duty Cycle |
Voltage |
Control Signal |
W (NEMA 4/4X, weathertight) WX (NEMA 4/4X/7/9, |
150 300 600 1000 1500 2000 2500 3000 |
A (Timer) B (Cycle Rate Regulator) C (Electronic Positioner) D (Center-off) R (Single Relay) R2 (Dual Relay) |
F (Visual Positioner Indicator) G (4-20mA Retransmit Board) K (Brake) P (Feedback Pot) S1/S2/S3 (Extra Limit Switches) T (Heater and Thermostat) Z (Handwheel) |
N (75%) |
115VAC 230VAC 12VDC 24VDC |
4-20mA 0-135 Ohm 0-10 VDC Other Signals |
|
N/A (NEMA 4 - weathertight standard) |
100 150 300 600 |
A (Timer) |
S1 (Extra Limit Switch) T (Heater and Thermostat) |
S (25%) |
115VAC 230VAC 24VAC 12VDC* 24VDC* |
N/A |
|
N/A (NEMA 4 - weathertight standard) |
100 150 300 600 |
A (Timer) D (Center-off) |
F (Position Indicator) S1/S2 (Extra Limit Switches) T (Heater and Thermostat) |
S (25%) |
115VAC 230VAC 24VAC 12VDC* 24VDC* |
N/A |
|
W (NEMA 4/4X, weathertight) WX (NEMA 4/4X/7/9, explosionproof) |
150 300 600 |
C (Electronic Positioner) CL2 (Fail-Safe Positioner) w/ Battery Back Up L2 (Fail-Safe) w/ Battery Back Up |
F (Visual Positioner Indicator) G (4-20mA Retransmit Board) K (Brake) P (Feedback Pot) S1/S2/S3 (Extra Limit Switches) T (Heater and Thermostat) |
S (Continuous) |
115VAC 230VAC 24VAC 12VDC 24VDC |
4-20mA 2-10 VDC Other Signals |
|
W (NEMA 4/4X, weathertight)
WX (NEMA 4/4X/7/9, explosionproof) |
1000 1500 2000 2500 3000 |
C (Electronic Positioner) CL3 (Fail-Safe Positioner) w/ Battery Back Up L3 (Fail-Safe) w/ Battery Back Up |
F (Visual Positioner Indicator) G (4-20mA Retransmit Board) K (Brake) P (Feedback Pot) S1/S2 (Extra Limit Switches) T (Heater and Thermostat) |
S (Continuous) |
115VAC 230VAC 24VAC 12VDC 24VDC |
4-20mA 2-10 VDC Other Signals |
|
W (NEMA 4, 4X - weathertight standard)
WX (NEMA 4/4X/7/9, |
50 300 600 |
Fail-Safe: Power Storage Board comes Standard. |
F (Position Indicator) K (Brake) S1/S2 (Extra Limit Switches) |
S (Continuous) |
115VAC 230VAC 24VAC 24VDC* |
N/A |
* DC Voltage LCU & LCR Series units have a continuous Duty Cycle.
All information is subject to change!